Gun
Gun
Gun Setup
Setup
Setup
Gun
Gun
Gun Setup
Setup
Setup Procedure
Procedure
Procedure
See the figure below to locate the electrostatic gun
controls.
Figure 15 Electrostatic Gun Controls
1.
Turn OFF (O) the ES On-Off switch (J).
2.
Shut off the air bleed valve to the gun.
3.
Check gun resistance.
See
4.
Connect the Graco grounded air hose to the gun
air inlet. The gun air inlet fitting has left-hand
threads.
5.
Follow all steps under
6.
Follow all steps under
Check Gun Electrical Grounding, page 24
.
Reading must be less than 1 megohm.
7.
Verify that the material resistivity meets
requirements for electrostatic spray. See
Check Fluid Resistivity, page 25
.
8.
Connect the exhaust tube and secure with the
clamp provided.
9.
Connect the fluid hose to the gun fluid inlet.
10. Flush if needed. See
.
3A2495K