Air
Air
Air Cap,
Cap,
Cap, Spray
Spray
Spray Tip,
Tip,
Tip, and
and
and Fluid
Fluid
Fluid Seat
Seat
Seat Housing
Housing
Housing Replacement
Replacement
Replacement
1.
See
Prepare the Gun for Service, page 39
.
2.
Remove the retainer ring (22) and air cap/tip
guard assembly (25).
Figure 20 Remove Air Cap
3.
Disassemble the air cap assembly. Check the
condition of the u-cup (22a), o-ring (25b), and tip
gasket (27a). Replace any damaged parts.
Figure 21 Disassemble Air Cap Assembly
Figure 22 Tip Gasket
4.
To replace the electrode (25a), see
Electrode Replacement, page 41
The conductive ring (9) is a conductive metal
contact ring, not a sealing o-ring. To reduce
the risk of fire, explosion, or electric shock:
• Do not remove the conductive ring except
to replace it.
• Never operate the gun without the conductive
ring in place.
• Do not replace the conductive ring with
anything but a genuine Graco part.
5.
Trigger the gun and remove the fluid seat housing
(24), using the multi-tool (61).
Figure 23 Replace Fluid Seat Housing
40