Pressure Relief Procedure
10
311189L
Pressure Relief Procedure
1.
While in Mix mode (dispensing mix material),
isolate the A and B fluid supply.
2.
Push the manual override on the A and B dispense
valve solenoids to relieve pressure.
3.
Purge mix material following the Purging section in
the ProMix
™
Auto Operation Manual (311079).
4.
Isolate the solvent fluid supply.
5.
Initiate purge sequence following the Purging
section in the ProMix
™
Auto Operation Manual
(311079).
6.
Verify the solvent pressure is reduced to 0.
F
IG
. 2: Wall Mount Fluid Supply Solenoids
Follow Pressure Relief Procedure when you stop
spraying, before changing spray tips, and before
cleaning, checking, or servicing equipment. Read
warnings, page 5.
NOTE: If Dose alarm occurs, clear alarm.
NOTE: If Purge Volume alarm occurs, clear
alarm.
Solenoid
Button
F
IG
. 3: RoboMix Fluid Supply Solenoids
Solenoid