Shutdown
311189L
11
Shutdown
Overnight Shutdown
There are two possible procedures for overnight shut-
down:
•
If flushing the system with solvent is required,
run Recipe 0 to purge solvent through meters
and gun; see ProMix
™
Auto Operation manual
(311079).
•
If flushing the system with solvent is NOT
required, release the gun trigger and put system
in Standby mode.
Service Shutdown
1.
Follow “Pressure Relief Procedure” on page 10.
2.
Close main air shutoff valve on air supply line and
on ProMix™ Auto.
3.
Shut off ProMix™ Auto power (0 position). F
. 4.
4.
If servicing EasyKey™ Display, also shut off power
at main circuit breaker.
•
To avoid electric shock, turn off EasyKey™ power
before servicing.
•
Servicing EasyKey™ display exposes you to high
voltage. Shut off power at main circuit breaker
before opening enclosure.
•
All electrical wiring must be done by a qualified
electrician and comply with all local codes and reg-
ulations.
•
Do not substitute system components as this may
impair intrinsic safety.
F
IG
. 4
0 = OFF