ProShot Repair Kit
3A0153E
17
ProShot Repair Kit
Outlet Valve Fitting
NOTE:
Before doing any repair to pump, perform
Flushing Sprayer
procedure, page 13.
Removal
1.
Engage trigger lock and pull relief valve UP to
release pressure.
2.
Remove battery.
3.
Remove pump outlet cap.
4.
Use tool (supplied) to loosen and remove outlet
valve fitting.
Installation
1.
Screw outlet valve fitting into threads. Use tool (sup-
plied) and tighten to 8 ft-lb.
2.
Press new pump outlet cap into place.
ti14994a
ti14999a
ti14996a
ti15503a
ti15506a
ti15508a
ti15507a