Maintenance
3A9019A EN
37
ProXChange Removal Tool
An integrated tool is included in the frame to
remove the ProXChange packing assembly.
See ProXChange Pump manual for complete
repair instructions.
Pump Installation
1. Slide pump assembly onto the
mounting pins.
a. Move pump rod up or down until
cap is level with the opening in the
yoke.
b. Push on pump rod to slide pump
assembly back on to mounting
pins.
2. Swing Easy Access Door closed while
pushing the entire door down.
3. Install hose, suction tube, and drain
tube.
NOTE:
Door must be fully closed and latched
before sprayer will operate.
ti27037a
1
ti27478a
2
3