Maintenance
36
3A9019A EN
, page 27 and
5. Inspect for leaks. If leaks occur, perform
then tighten all fittings and repeat step 3.
Pump Repair
When pump packings wear, paint will begin
to leak down outside of pump. Purchase a
pump repair kit and install according to
instructions provided with kit, before your
, page 46, or consult a Graco/MAGNUM
authorized retailer, distributor, or service
center.
Each time the pump kit is replaced, check
pump inlet and outlet valves for wear or
damage. Replace if worn or damaged.
Always replace inlet and outlet valves every
second time the pump kit is replaced.
Pump Removal
Remove airless hose, suction tube, and drain
tube. Always perform
, page 15 before starting any
pump repairs.
1. Perform Pressure relief procedure, see
2. Pull tabs on sides of the easy access
door towards you while pushing the
entire door up.
3. Now lift the door so that it swings out of
the way.
4. Slide pump assembly off the mounting
pins.
.
High-pressure spray is able to inject
toxins into the body and cause serious
bodily injury. Do not stop leaks with hand
or rag.
1
3
ti27463a
2