background image

Installation 

2

3A8507C

Installation

Set Up

Connecting to a Network

Summary 

Please refer to the instructions in this section, unless 

indicated otherwise.

1. Press and hold the button on the top of the Pulse 

sensor until the LED light turns red.

2. Using a mobile device (e.g. laptop, smart phone, 

tablet), search for a WiFi network beginning with 

GRACO and connect.

3. Open a web browser and enter “192.168.4.1” into 

the address bar.

4. After the WiFi settings page is loaded, select the 

intended WiFi network from the drop down bar.

5. Enter the selected WiFi network password.

6. Click the Connect to WIFI button.

7. The LED on the Pulse sensor turns green (F

IG

. 3).

8. Wait approximately 20 seconds. 

9. The sensor flashes red or green several times. 

• Green flashes indicate that a connection to the 

network has been established.

• Red flashes indicate that a connection to the 

network has not been established. The number of 

red flashes identifies the problem:

NOTICE

• Do not over tighten TLM into tank bung. Over 

tightening can cause permanent damage and 

result in inaccurate readings.

• Do not use the TLM with pressurized tanks. Using 

the TLM in a pressurized tank will damage the 

TLM.

• Do not use thread sealant or adhesive. Many of 

these products are chemically incompatible with 

the ABS plastic threads.

F

IG

. 1

F

IG

. 2

F

IG

. 3

LED light

Summary of Contents for Pulse 25T460

Page 1: ...can cause death or serious injury Do not alter or modify equipment Alterations or modifications may void agency approvals and create safety hazards Make sure all equipment is rated and approved for t...

Page 2: ...k password 6 Click the Connect to WIFI button 7 The LED on the Pulse sensor turns green FIG 3 8 Wait approximately 20 seconds 9 The sensor flashes red or green several times Green flashes indicate tha...

Page 3: ...ss steel self tapping counter sunk screws included with kit to attach the adapter to the tank Do not over tighten 4 Attach the sensor to the adapter To form a secure seal make sure that the sensor is...

Page 4: ...ll 3 Continue with Mount Options steps 1 through 4 Operation View Data The TLM can be configured with the Pulse Level level gracopulse com to take a reading at predefined times After configuring the T...

Page 5: ...gs Out of WiFi range WiFi obstruction Ensure that the TLM is not encased in metal since this would obstruct the signal Take a manual measurement and review LEDs during the measurement Weak or dead bat...

Page 6: ...ize battery See Technical Specifications page 8 for battery information Install the battery as shown in FIG 9 with the positive end on the right This is the clip that has shrink tubing on it 5 To main...

Page 7: ...llons or liters Tank end walls must be flat they cannot be any other shape including belled Obround Tank Maximum volume 999 999 gallons or liters Tank end walls must be flat they cannot be any other s...

Page 8: ...2 GHz 2 462 GHz Maximum RF Transmit Power 18 dBm Operating Temperature Range 0 F to 122 F 17 8 C to 50 C Storage Temperature Range 0 F to 122 F 17 8 C to 50 C Batteries Li SOCl2 Size R14 3 6V C cell B...

Page 9: ...MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE Graco s sole obligation and buyer s sole remedy for any breach of warranty shall be as set forth above The buyer agrees that no other re...

Page 10: ...hanges at any time without notice Original instructions This manual contains English MM 3A8507 Graco Headquarters Minneapolis International Offices Belgium China Japan Korea GRACO INC AND SUBSIDIARIES...

Reviews: