Setup
313221A
15
4.
Connect fluid hoses
Connect fluid supply hoses to outlet
hose connections (R, F
IG
. 6). Fittings
are sized to prevent connection errors.
Connect other end of hoses to A and B
inputs of gun.
5.
Connect gun air hose
Connect gun air hose to the gun air
input and to the air filter outlet (Z). If you
are using more than one hose bundle,
join the air hoses with the nipple (305)
provided with the hose bundle.
On heated units with Fusion guns, con-
nect the supplied ball valve and
quick-disconnect coupler to the gun air
hose, then connect the coupler to the
gun air fitting.
6.
Turn on air compressor
Turn on air compressor power. Set regu-
lator to desired output pressure as indi-
cated on the gauge.
Air Filter/Moisture Separator (Z) is
equipped with an automatic moisture
drain.
7.
Flush before first use
The Reactor E-10 is tested with a plasti-
cizer oil at the factory. Flush out the oil
with a compatible solvent before spray-
ing. See page 24.
F
IG
. 6. Hose Connections
R
Z