Setup
16
313221A
8.
Fill wet-cups
Keep the felt washers in the pump
wet-cups saturated with Owens Corning
plasticizer; see Owens Corning Distribu-
tor. The lubricant creates a barrier
between the red fluid and the atmo-
sphere.
9.
Install suction tube
CAUTION
To prevent cross-contamination of fluids and
equipment parts, never interchange compo-
nent A and component B parts or containers.
Label one pail “A” and the other “B”, using
the labels provided. Always doublecheck
which material you have before placing suc-
tion tubes in pails.
Fill wet-cups through slots
in plate, or loosen screws
and swing plate aside.
TI6985a
Pump rod and connecting rod move during
operation. Moving parts can cause serious
injury such as pinching or amputation. Keep
hands and fingers away from wet-cup dur-
ing operation. Shut off Motor Power
before filling wet-cup.
Using a drill and mixing blade, mix filled or
separated materials in the pail. Material
left in the tanks overnight may need to be
remixed.
a.
Open red and white fluid pails
and position in front of suction
tubes.
b.
Stand behind unit and hold cross-
bar. Lean unit backwards until the
suction tubes are above the sup-
ply pails.
c.
Place suction tubes in pails.
A
B
A
B