Flushing
24
313221A
Flushing
•
Generally, flush if you will be shut down for
more than 3 days. Flush more often if mate-
rial is moisture sensitive and humidity is
high in the storage area, or if material may
separate or settle out over time.
•
Flush out old fluid with new fluid, or flush
out old fluid with a compatible solvent
before introducing new fluid.
•
Use the lowest possible pressure when
flushing.
•
Always leave some type of fluid in system.
Do not use water.
•
For long term storage, flush out the solvent
with a storage fluid such as Bayer Mesa-
moll plasticizer or, at minimum, clean motor
oil.
Flush equipment only in a well-ventilated
area. Do not spray flammable fluids. Do not
turn on heaters while flushing with flamma-
ble solvents.
1.
Engage piston safety lock. Close fluid
valves A and B. Leave air on.
Fusion
2.
Set function knob to Stop/Park
.
3.
Shut off Heater Power (heated units
only). Allow system to cool.
4.
Unlatch straps and remove A and B
pails from mounting bracket. Stand
behind unit and hold crossbar. Lean unit
backwards to remove suction tubes from
A and B fluid pails.
5.
Fill two pails with 1-2 gal. (3.8-7.6 l) of
solvent recommended by your material
manufacturer. Insert suction tubes in
solvent pails (SP).
A
B