Flushing
313221A
25
6.
Disconnect recirculation tube (N) and
insert in waste container (W).
7.
Turn Recirc/Spray valves to Recirc.
8.
Set function knob to Fast Recirc
.
Pump solvent through system to waste
containers.
9.
When nearly clear solvent comes from
recirculation tubes, set function knob to
Stop/Park .
Place
recirculation
tubes in solvent pails.
10.
Set function knob to Fast Recirc
.
Circulate solvent through system for
10-20 minutes to ensure thorough
cleaning.
N
SP
SP
W
To flush gun, refer to gun instruction
manual.
Purge Gun Hoses
Disconnect hoses from gun and secure
back into the tanks for thorough cleaning
with solvent.
•
Turn Recirc/Spray valve A to Spray.
•
Open gun into waste container A.
•
Set function knob to Slow Recirc
until hose is flushed.
•
Set function knob to Stop/Park
.
•
Repeat for B side.
11.
Set function knob to Stop/Park
.
12.
Solvent flushing is a two step process.
Go back to step 4, drain solvent, and
flush again with fresh solvent.
13.
Leave unit filled with solvent, plasticizer,
or reprime with new material.
Never leave the unit dry unless it has
been disassembled and cleaned. If fluid
residue dries in the pumps, the ball
checks may stick the next time you use
the unit.