Technical Data
76
332144E
Technical Data
Reactor E-10hp
US
Metric
Maximum fluid working pressure
3000 psi
20.6 MPa, 206 bar
Maximum spray pressure: 120 V
2200 psi
15.2 MPa, 152 bar
Maximum spray pressure: 230 V
2500 psi
17.2 MPa, 172 bar
Maximum fluid temperature
170°F
77°C
Maximum ambient temperature
120°F
48°C
Maximum output
1 gal./min
3.8 liters/min
Output per cycle (ISO and RES)
0.0038 gallons/cycle
0.014 liters/cycle
Air inlet
1/4 in. quick-disconnect industrial type pin fitting
Air outlet
1/4 npsm(m)
Overpressure relief
Recirc/Spray valves automatically relieve excessive fluid pressure back to
supply tanks
Gun compressed air requirements
Fusion Gun (purge air and operating air): 4 scfm (0.112 m
3
/min)
Maximum hose length
105 ft
32 m
Tank capacity each (nominal)
6 gal.
22.7 liters
Weight (empty)
239 lb
108 kg
Recommended Mix Chamber Sizes
Fusion
®
Air Purge
000, AW2222 (00 and 01 at reduced spray pressure)
Probler
®
P2
AA (00 and 01 at reduced spray pressure)
Electrical Requirements
120 V
100-120VAC, 1 phase, 50/60 Hz, 3840 W; requires two separate,
dedicated 20 A circuits. Full load peak amperage 16 A per circuit.
230 V
200-240VAC, 1 phase, 50/60 Hz, 5520 W; requires two separate,
dedicated 15 A circuits. Full load peak amperage 12 A per circuit.
Generator Size
120 V
5000 W minimum
230 V
7500 W minimum
Heater Power
120 V
3000 W during recirculation, 2000 W during pressure spray mode
230 V
4000 W during recirculation, 2760 W during pressure spray mode
Sound Pressure
In fast recirculation mode
71.3 dB(A)
Measure at 2500 psi (17 MPa, 172
bar), 1 gpm (3.8 lpm)
85.6 dB(A)
Sound Power*
In fast recirculation mode
79.9 dB(A)
Measure at 2500 psi (17 MPa, 172
bar), 1 gpm (3.8 lpm)
93.3 dB(A)