Diagnostic Codes
39
Motor Control Diagnostic Codes
Motor control diagnostic codes E21 through
E27 appear on pressure display.
There are two types of motor control codes:
alarms and warnings. Alarms take priority over
warnings.
See repair manual for corrective action.
Alarms
Alarms turn off Reactor. Turn main power OFF
then ON
to clear.
Warnings
Reactor will continue to run. Press
to
clear. A warning will not recur for a predeter-
mined amount of time (varies for different
warnings), or until main power is turned OFF
then ON
.
Alarms can also be cleared, except for
code 23, by pressing
.
Code 24 (pressure imbalance) is set to
an alarm default of 500 psi (3.5 MPa, 35
bar). To change to a warning, see Reac-
tor Repair-Parts manual 312063. To
change the default pressure imbalance
setting, see page 30.
Code
No.
Code Name
Alarm or
Warning
21
No transducer (component A)
Alarm
22
No transducer (component B)
Alarm
23
High pressure
Alarm
24
Pressure imbalance
Selectable;
see repair
manual
27
High motor temperature
Alarm
30
Momentary loss of communi-
cation
Alarm
31
Pumpline switch failure/high
cycle rate
Alarm
99
Loss of communication
Alarm