Repair
309813B
31
Replace Transformer
2.
Open Reactor cabinet.
3.
Remove bolts holding transformer to cabinet floor.
Slide transformer forward.
4.
Unplug 3-pin wire harness connector (C) from wire
harness coming from temperature control board.
5.
Remove transformer from cabinet.
6.
Install new transformer in reverse order.
Use this procedure to replace transformer. To
replace terminal block (B) and wire harness (C)
only, order Part No. 248113 Transformer Repair
Kit. See manual 309930.
1.
Turn main power OFF
. Disconnect power
supply.
WARNING
Read warnings, page 8. Wait 5 min for stored voltage
to discharge (E-30 and E-XP2 models only).
F
IG
. 10. Transformer
TI3470b
C
T4
B
R
TI3934a
TI2514A
806
817A
PA
PC
Detail A: Terminal Block
Detail B: Circuit Breaker Module