Repair
18
309813B
Circuit Breaker Module
2.
Relieve pressure, page 11.
3.
Using an ohmmeter, check for continuity across cir-
cuit breaker (top to bottom). If no continuity, trip
breaker, reset, and retest. If still no continuity,
replace breaker as follows:
a.
Refer to electrical diagrams and to T
1. Dis-
connect wires and remove bad breaker.
b.
Install new breaker and reconnect wires.
* Depending on model.
1.
Turn main power OFF
. Disconnect power
supply.
WARNING
Read warnings, page 8.
Table 1: Circuit Breakers, see F
Ref. No.
Size
Component
806
50 A
Hose/Transformer
Secondary Side
817A
20 A
Transformer
Primary
804A
25 or 40 A*
Heater A
804B
25 or 40 A*
Heater B
817B
20 A
Not Used
F
IG
. 2. Circuit Breaker Module
TI2514A
804A
817B
806
817A
NOTE: To reference cables and con-
nectors, see the electrical diagrams and
the parts drawings on pages 51-53.
804B