Electro-pneumatic Control Panel Display Screens
ELECTRIC
ELECTRIC
ELECTRIC SHOCK
SHOCK
SHOCK HAZARD
HAZARD
HAZARD
To reduce the risk of electric shock when
accessing the electrical enclosure while power
is present:
• All electrical work must be done by a
qualified electrician.
• Wear appropriate personal protective
equipment.
Event
Event
Event
Type
Type
Type
Event
Event
Event Description
Description
Description
Error
Error
Error
Code
Code
Code
Cause
Cause
Cause
Fix
Fix
Fix
Alarm
Communication bus
power error
V1CC
Communication bus has lost
power
Restore power to communication
bus.
Alarm
Control panel supply
pressure low
P1PS
Control supply pressure sensor
reads pressure less than the
minimum 30 psi required for
operation or less than 5 psi
below largest pressure required
by the current recipe
Increase supply air pressure or
reduce pressure required by the
current recipe.
Alarm
Control supply
pressure sensor
error
WMPC
Control supply pressure
sensor reports an error
Check control supply pressure sensor
and wiring.
Alarm
Emergency stop or
I/O power error
V1CE
I/O has lost power
Restore I/O power, reset E-stop
button.
Alarm
External interlock #1
open
EBN1
Interlock #1 is enabled and
tripped
Close or disable interlock #1.
Alarm
External interlock #2
open
EBN2
Interlock #2 is enabled and
tripped
Close or disable interlock #2.
Alarm
Laser position
sensor error
WMCL
Laser sensor reports an error
Check laser sensor and wiring.
Alarm
Laser sensor
obstructed
L9CL
An obstruction or unintended
target of the position sensor
has been detected
Ensure the laser has a clear line of
sight to the target.
Alarm
Network
Communication
Error
CC0R
Remote network communica-
tion is enabled, but the remote
device cannot be found
Verify that the IP addresses of the
system and the remote controller
are correct. Verify that the system
and the remote controller are on the
same network. Verify that the remote
controller is properly configured as
described in
.