Cleanup
3A7653D
21
9.
Allow water to flow out of drain tube and
into waste bucket until approximately 1/3
of the water is emptied from the Hopper.
10. Turn ON/OFF Switch to
OFF
position.
NOTE:
Step 11 is for removing disinfectant
from the Airless Hose. One 50 ft Airless
Hose holds approximately 1 quart of fluid.
11. To remove disinfectant from Airless
Hose:
a.
Hold Spray Gun against waste
bucket.
b.
Disengage Trigger Lock.
c.
Pull and hold Spray Gun trigger.
d.
Turn Prime/Spray Valve up to
SPRAY position.
e.
Turn ON/OFF switch to
ON
position.
12. Continue triggering Spray Gun into
waste bucket until all water is emptied
from the Hopper and Airless Hose.
*
13. Stop triggering Spray Gun. Engage the
Trigger Lock.
14. Turn Prime/Spray Valve horizontal to
PRIME position.
15. Turn ON/OFF Switch to
OFF
position.
16. Dispose of the fluid in the waste bucket
according to the instructions on the
disinfectant container label and
applicable regulations.
Clean the Gun
1.
Remove Spray Tip and Spray Tip Guard
assembly. Clean with water and a brush.
2.
Wipe sprayer, Airless Hose, and Spray
Gun with soft cloth moistened with water.