309246 15
Repair
Turbine/Motor Replacement
The System 2500
, System 3800
, and System
4900
Turbine Sprayers each use a different
turbine/motor. See the Turbine/Motor Replacement
Kits in the Parts List on page 17 for a listing of
replacement kit parts.
See parts drawing on page 17.
1.
Use System HVLP Turbine Sprayer
Disassembly procedure on page 14 to take
turbine apart.
2.
Remove turbine gasket (25).
3.
Loosen 3 screws (6) and remove.
4.
Remove plate (82) and 3 spacers (83).
5.
Remove turbine motor wires from spade
connectors.
6.
Rotate turbine (24) from outlet fitting (18) and lift
up from turbine spacers (23).
7.
Install new turbine gaskets (25 and 41).
8.
Reassemble turbine.
9.
Connect ground wire to turbine housing as
required.
10. Reconnect wires according to applicable turbine.
See Fig. 10, Fig. 11, or Fig. 12 schematics.
GROUND
L
N
G
L1
L2
G
System 2500
t
Fig. 10
Motor
Fig. 11
System 3800
t
Motor
7245A
Fig. 12
7244B
System 4900
t
Motor
Summary of Contents for System 3800