22
309977
Drive Housing
Removal
1.
Relieve pressure
;
page 4.
2.
Fig. 5. Remove pump module (A).
a.
Loosen clamp rod (20).
b.
Release hopper quick-release clamp (28).
c.
Disconnect pump module (A) from frame (35).
3.
Fig. 6. Remove five screws (12 ) and motor cover
(18).
4.
Fig. 21. Lay pump module horizontal. Remove four
screws (90) and washers (71) and gear housing
base (25).
5.
Remove two screws (86) and washers (84) from
front of drive housing.
6.
Disconnect transducer lead (E) from control board
(38). Pull strain relief bushing (49) from circuit
board bracket (21). Thread transducer connector
through circuit board bracket.
7.
Remove bearing housing and pump assembly:
a.
Remove four screws (7) and lock washers (6)
from bearing housing (34).
b.
Pull connecting rod assembly (45) and lightly
tap lower rear of bearing housing with a plastic
mallet to loosen bearing housing from drive
housing (37). Pull bearing housing and pump
assemblies from drive housing.
c.
Inspect crank (G) for excessive wear and
replace drive housing, if necessary.
8.
Return motor and drive housing assembly to
vertical position.
9.
Remove two screws (12) and circuit board bracket
(21) from from drive housing (37).
10. Remove four screws (85) and washers (84).
CAUTION
Do not drop combination gear (29) and thrust wash-
ers (10,11,14) when removing drive housing (37).
Combination gear and thrust washers may stay
engaged in motor front end bell or drive housing.
11. Lightly tap around drive housing (37) to loosen
from motor (33). Pull drive housing straight off
motor. Be prepared to support combination gear
(29) and thrust washers (10,11,14) which may also
come out.
12. Remove combination gear (29) and thrust washers
(10,11,14) that do not come out.
ti5019a
7
6
25
37
10
11
33
71
85
84
84
86
90
14
29
34
Fig. 21
1
1
Liberally apply bearing grease
G
H
Summary of Contents for T-Max 405 248195