Airless Spray

1. Be sure the arrow shaped tip (19) faces forward 

(spray).

2. Hold applicator perpendicular and approximately 

40 in. (1 m) from surface. Move applicator first, then 
open applicator to spray a test pattern.

3. Slowly increase pump pressure until coverage is 

uniform and even (see sprayer instruction manual 
for additional information).

Aligning Spray

1. Perform 

Pressure Relief Procedure

, page 4.

2. Loosen guard retaining nut.

3. Align guard (18) horizontally to spray a horizontal 

pattern.

4.

Align guard (18) vertically to spray a vertical pattern.

Clear Tip Clog

To avoid tip clogs:

When the applicator is not in use for extended 
periods of time, keep the tip “wet” and perform 

Pressure Relief Procedure

, page 4.

Keep tip clean and free of material.

1. Rotate SwitchTip to unclog position. Aim applicator 

at floor and turn applicator ON. When clog clears, 
turn applicator OFF.

UNCLOG

2. Rotate SwitchTip back to spray position. Turn 

applicator ON. Spray test pattern.

SPRAY

Air Spray

1. Set material flow (see sprayer instruction manual for 

additional information).

2. Spray test pattern

3. Turn air knob on and adjust, and/or select another 

air nozzle, for desired pattern.

NOTE

: Air continues to flow when handle is in off 

position to keep material out of air passages.

Cleanup

Flush applicator after each work shift and store in a dry 
location. Do not leave the applicator or any parts in 
water or cleaning solvents.

(4) Vertical

 

(

3) Horizontal

ti11908a

ti11909a

ti11714a

ti11794a

ti11715a

ti11793a

Summary of Contents for T-Max Applicator 17Z054

Page 1: ...are used For professional use only Not approved for use in European explosive atmosphere locations Models 256383 17Z054 1000 psi 6 9 MPa 69 bar Maximum Fluid Working Pressure 250 psi 1 7 MPa 17 bar Maximum Air Working Pressure Important Safety Instructions Read all warnings and instructions in this manual and in the T Max operation manual before using the equipment Save these instructions Related ...

Page 2: ...area free of debris including solvent rags and gasoline Do not plug or unplug power cords or turn power or light switches on or off when flammable fumes are present Use only grounded hoses Hold gun firmly to side of grounded pail when triggering into pail Do not use pail liners unless they are anti static or conductive Stop operation immediately if static sparking occurs or you feel a shock Do not...

Page 3: ...vironment in which you are using it Use equipment only for its intended purpose Call your distributor for information Route hoses and cables away from traffic areas sharp edges moving parts and hot surfaces Do not kink or over bend hoses or use hoses to pull equipment Keep children and animals away from work area Comply with all applicable safety regulations PRESSURIZED ALUMINUM PARTS HAZARD Use o...

Page 4: ... b VERY SLOWLY loosen the retaining ring 10 hose end coupling 43 or pressure relief valve on the sprayer to relieve pressure gradually c Loosen the nut or coupling completely d Clear the obstruction in the hose or tip NOTE If pressure relief valve was used to relieve pressure be sure to disassemble and clean thoroughly This equipment stays pressurized until pressure is manually relieved To help pr...

Page 5: ... lowest pressure possible Check con nectors for leaks and tighten as necessary Do not leave the applicator or any parts in water or cleaning solvents 1 Follow Pressure Relief Procedure page 4 2 Remove the spray tip and guard by loosening retaining ring 10 3 Hold a metal part of the gun firmly to a grounded metal pail Trigger the gun until clean solvent dispenses 4 Store in a dry location To avoid ...

Page 6: ... into back of guard 18 3 Install guard 18 onto end of applicator 9 4 Insert tip 19 in guard 18 Tighten retaining nut Air Spray Setup Connect Applicator to Sprayer 1 Attach supply hose to sprayer fluid outlet 2 Attach other end of supply hose to applicator swivel 17 3 Install air hose to applicator check valve 8 4 Refer to sprayer instruction manual for priming instructions Install Applicator Air N...

Page 7: ...nded periods of time keep the tip wet and perform Pressure Relief Procedure page 4 Keep tip clean and free of material 1 Rotate SwitchTip to unclog position Aim applicator at floor and turn applicator ON When clog clears turn applicator OFF UNCLOG 2 Rotate SwitchTip back to spray position Turn applicator ON Spray test pattern SPRAY Air Spray 1 Set material flow see sprayer instruction manual for a...

Page 8: ...g 1 33 277789 SUPPORT filter 2 34 15U687 SEAL adapter filter texture 1 35 289923 FILTER screen texture 30 mesh includes 33 1 36 289917 SEAT spool valve includes 7 1 37 17Z185 KIT accessories air assist 1 37a 112779 VALVE needle 1 37b 156823 FITTING union swivel 1 37c 15C899 HOSE cpld air 9 5mm x 15m 1 37d 248524 NOZZLE 4mm 1 37e 248525 NOZZLE 6mm 1 37f 248526 NOZZLE 8mm 1 37g 248527 NOZZLE 10mm 1 ...

Page 9: ...ADAPTER GHD RAC 1 13 107110 LOCKNUT 2 14 108193 WASHER plain 2 15 514237 SCREW cap sch 10 32 x 1 1 2 2 17 289920 SWIVEL assy texture heavy 1 18 246215 GUARD RAC X 1 19 HDA651 TIP spray RAC X 651 1 20 246453 KIT gasket and seat 5 sets 1 27 248524 NOZZLE 4 mm rnd 1 30 121548 WASHER plain 1 31 121549 RING retaining E ring 1 33 277789 SUPPORT filter 2 34 15U687 SEAL adapter filter texture 1 35 289923 ...

Page 10: ...re with washer 30 and clip 31 4 Install plate 2 onto spool note location of orientation hole Install handle with screw washer and nut 5 Apply grease to o ring 7 Install seat 36 o ring 7 and swivel 17 Technical Data Maximum fluid working pressure 1000 psi 6 9 MPa 69 bar Maximum air working pressure 250 psi 1 7 MPa 17 bar Air Requirements 30 scfm 0 84 m3 min Maximum Fluid Inlet Size 1 in m cam and g...

Page 11: ...s of parts labor and transportation THIS WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ANY OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE Graco s sole obligation and buyer s sole remedy for any breach of warranty shall be as set forth above The buyer agrees that no other remedy including but not limited to inci...

Page 12: ...polis International Offices Belgium China Japan Korea GRACO INC AND SUBSIDIARIES P O BOX 1441 MINNEAPOLIS MN 55440 1441 USA Copyright 2008 Graco Inc All Graco manufacturing locations are registered to ISO 9001 www graco com Revision E April 2019 Graco Information For the latest information about Graco products visit www graco com For patent information see www graco com patents TO PLACE AN ORDER c...

Reviews: