Operation
312879E
7
Operation
Airless Spray
1. Be sure the arrow shaped tip (19) faces forward
(spray).
2. Hold applicator perpendicular and approximately
40 in. (1 m) from surface. Move applicator first, then
open applicator to spray a test pattern.
3. Slowly increase pump pressure until coverage is
uniform and even (see sprayer instruction manual
for additional information).
Aligning Spray
1. Perform
2. Loosen guard retaining nut.
3. Align guard (18) horizontally to spray a horizontal
pattern.
4.
Align guard (18) vertically to spray a vertical pattern.
Clear Tip Clog
To avoid tip clogs:
•
When the applicator is not in use for extended
periods of time, keep the tip “wet” and perform
•
Keep tip clean and free of material.
1. Rotate SwitchTip to unclog position. Aim applicator
at floor and turn applicator ON. When clog clears,
turn applicator OFF.
UNCLOG
2. Rotate SwitchTip back to spray position. Turn
applicator ON. Spray test pattern.
SPRAY
Air Spray
1. Set material flow (see sprayer instruction manual for
additional information).
2. Spray test pattern
3. Turn air knob on and adjust, and/or select another
air nozzle, for desired pattern.
NOTE
: Air continues to flow when handle is in off
position to keep material out of air passages.
Cleanup
Flush applicator after each work shift and store in a dry
location. Do not leave the applicator or any parts in
water or cleaning solvents.
(4) Vertical
(
3) Horizontal
ti11908a
ti11909a
ti11714a
ti11794a
ti11715a
ti11793a