Setup/Startup
3A8108A
21
Calibration
1.
Check rear tire pressure and fill to 55 +/-
5 psi (379 +/- 34 kpa), if necessary.
2.
Extend steel tape to 25 ft (8 m) or longer.
3.
Move pointer to rear position.
4.
Press
to select SETUP/INFO.
5.
Press
for Calibration. Set TRAVEL
DIST to 24 ft (7 m) or longer. Longer
distances ensure better accuracy,
depending on conditions.
6.
Set guide and align with one foot mark on
steel tape, as shown in picture.