Setup
309915D
9
Reinstalling Compressor Power Pack (Z)
Note: For maximum performance
use a 3/8 in. or 1/2 in. inside
diameter hose.
Hose must be rated for:
•
200°F (93°C) maximum
temperature
•
125 psi or greater
1 Disconnect air hose from the
compressor power pack quick
disconnect fitting (dd) and from
the cart air quick disconnect
fitting (V).
2 Inspect cart and compressor
power pack (Z). Remove any
debris or dirt on side rails of
cart and/or compressor power
pack.
3 Using handles, lift compressor
power pack (Z) onto cart
frame.
4 Push compressor power pack
(Z) forward, until front edge
meets tabs on cart base.
5 Lift and turn motor lock knob
(S) until compressor power
pack (Z) is securely attached
to cart.
6 Attach air line quick connect fitting (Q) to compressor air quick con-
nect inlet fitting (V).
,
ti3959a
ti3782a
tabs
S
Q
V