Pressure Control Board
311365G
25
110 Vac U.K. Filter Board
Removal
Relieve pressure; page 9.
Wait 5 minutes before servicing.
1. Remove four screws (38) and cover (96).
2. Disconnect display connector (A) from
motor control board (52).
3. Remove bottom two screws (39).
Disconnect potentiometer connector (C)
from motor control board (52). Disconnect
filter board connector (J) and power cord
connector (D) from ON/OFF switch (33).
Remove control panel (68).
4. Disconnect motor board control power
connectors (K) from filter board (146).
Disconnect filter connector (L) from power
cord connector (L).
5. Remove four screws (163) from filter board
(146).
Installation
1. Connect motor control board power
connectors (K) to filter board (146).
Connect filter connector (L) to power cord
connector (L).
2. Install filter board (146) with four screws
(163).
3. Connect filter board power connector (J)
and power cord connector (D) to ON/OFF
switch (33).
4. Connect potentiometer connector (C) to
motor control board (52).
5. Install control panel (68) with two screws
(39).
6. Connect display connector (A) to motor
control board (52).
7. Install cover (96) with four screws (38).