10. Open bleed type master air valve (B).
B
ti21574a
Figure 21
NOTICE
NOTICE
NOTICE
To prevent damage to pump seals caused by
cavitation, run the pump slowly until the system
is primed.
11. Rotate the air regulator adjustment knob (F)
clockwise until pump begins to move slowly.
F
ti21570a
Figure 22
12. Continue running the pump until a steady stream
of material comes from the applicator.
ti21632a
Figure 23
13. To stop dispensing, close the motor ON/OFF
pilot ball valve (G). Do not close the fluid ball
valve (V) when the air motor is running.
t
i21579a
Figure 24
14. Place the applicator outlet into the hopper.
15. With the fluid ball valve (V) open, open the motor
ON/OFF pilot ball valve (G). Material will begin
dispensing.
16. Recirculate a few gallons of material to be sure
the material is flowing properly.
17. Install a tip onto applicator. The system is now
primed and ready to spray.