Common Procedures
334179B
21
Unclogging Spray Tip
In the event that particles or debris clog the
spray tip, this sprayer is designed with a
reversible spray tip that quickly and easily
clears the particles without disassembling the
sprayer.
1.
Perform
Pressure Relief Procedure
,
page 16
.
2.
To unclog spray tip, turn Prime
Pump/Spray knob down to Prime Pump
position.
3.
Reverse spray tip to UNCLOG position.
4.
Dual speed models:
Move speed control switch to HIGH
setting.
5.
Variable speed models:
Set speed control to 10.
6.
Aim sprayer at waste area, turn Prime
Pump/Spray knob forward to spray
position. Pull trigger to clear clog.
7.
Turn Prime Pump/Spray knob down to
Prime position. Rotate spray tip back to
SPRAY position. Turn Prime
Pump/Spray knob forward to SPRAY
position, and resume spraying.
8.
If spray tip is still clogged, you may have
to repeat steps 2 - 7, or replace with new
spray tip assembly. See
Installing
Spray Tips
, page 20.
ti23285a
Prime Pump
ti23290a
SPRAY
UNCLOG
ti23359a
10
ti25737a
ti23288a
Spray