Common Procedures
334179B
23
6.
Align VacuValve on cup cover with
Prime Pump/Spray knob. Push cup
assembly onto sprayer and twist to lock.
7.
Plug sprayer into power source.
8.
Make certain the Prime Pump/Spray
knob is in the Prime Pump position
(pointed down). On models with a dual
speed control switch, set speed control
to HIGH. On variable speed models set
speed control to 10.
9.
Turn the sprayer upside down and point
the sprayer into a waste pail. Pull the
trigger for three seconds.
10. Turn Prime Pump/Spray knob forward to
SPRAY position. Rotate spray tip 180
degrees to UNCLOG position.
11. While holding the sprayer upside down
point the sprayer into a waste pail. Pull
the trigger for three seconds.
IMPORTANT!
For best results, do not spray
more than one cup of water through the tip
while cleaning. If more flushing is needed,
remove the tip from the sprayer to avoid
excessive wear.
12. Sprayer is now flushed and ready for
use. See
Start Up
, page 10.
IMPORTANT!
The motor has a built-in feature
to protect itself from overuse. If the motor
stops, the thermal switch has tripped.
Do not return sprayer to store.
The motor
will operate normally after cooling for 20-30
minutes.
ti23258b
ti23388a
ti23389a