Grounding
10
311365H
Grounding
1. Ultra Max II 695, 795 and 1095 100-200 Vac
models require a 50/60 Hz, 15A circuit with a
grounding receptacle. Ultra Max II 1595/Mark V
120 Vac models require a 50/60 Hz 20A circuit
with a grounding receptacle; 220-240 Vac
models require a 50/60 Hz, 10A circuit with a
grounding receptacle.
2. Do not alter ground prong or use adapter.
3. 120 Vac: A 12 AWG, 3 wires with grounding
prong, 300 ft (90 m) extension cord may be
used. 220-240 Vac: You may use a 3-wire, 1.0
mm (12 AWG) (minimum) extension cord up to
90 m long. Long lengths reduce sprayer
performance.
Improper installation or alteration of grounding
plug results in risk of electric shock, fire or
explosion that could cause serious injury or
death.