Operation
313873J
31
b.
Place a waste container below the ratio check
valves. The next steps will cause the machine
to dispense material.
c.
Press
then
. The pump will travel to
bottom-most position.
d.
After the pump stops moving, press
then
press
. The pump will travel to the top-most
position.
NOTE:
During this process, the system learned the
mechanical limits of piston travel. If the pump did not
reach either piston mechanical travel limit for any rea-
son, repeat the procedure.
21. Press
to exit the Setup screens.
22. Press
repeatedly to select Operator mode
then press
to accept.
23. Press
to enter the Setup screens then press
left or right to navigate to the main Calibration
screen.
Flow Meter / No Flow Meter Calibration
24. If flow meters are installed, refer to
meters are not installed, refer to
Flow Rate and Ratio Learning
25. At the main Calibration screen, press
to erase
all learned data.
NOTE:
This will not affect the weight calibration that was
just completed.
26. Press
to exit the Setup screens.
27. Press
repeatedly to select Shot mode then
press
to accept.
28. Select a defined shot that will provide a 10 second
or longer dispense at the flow rate and ratio
intended to be used during normal system opera-
tion.
NOTE:
Changes to the ambient temperature will affect
the maximum flow rate for the system. If the ambient
temperature decreases, the flow rate should be
decreased.