Appendix B - ADM Setup Screens Overview
313873J
61
System #1
This screen allows the user to set mechanical system
settings and the Dispense Mode setting.
Dispense mode can be set to time, volume, or weight.
Dispense mode controls how dispense quantities are
measured. Dispensing must be calibrated, see
on page 29 for more informa-
tion.
Pump sizes and inlet pressures must be entered on this
screen. The inlet pressure is the minimum allowable
fluid inlet pressure. If the inlet pressure is below this
value, dispensing is disabled. If pump sizes and inlet
pressures are not entered properly, system perfor-
mance will be affected.
System #2
This screen allows the user to set the Gel Timer proper-
ties and set which items are installed on the machine.
When enabling the Gel Timer, the user must select one
of the 100 available shot definitions to use as the Gel
Shot. This shot will be dispensed when the Idle Period
expires. The Idle Period will begin after a dispense is
completed. Any dispense operation in the middle of the
timer countdown will reset the Idle Period counter. The
system will generate an audible alarm that will begin the
user-entered number of seconds before the Idle Period
expires.
The hydraulic level sensor and hydraulic RTD for the
pump line must be enabled when installed in the sys-
tem. If the sensors are not marked as enabled, they will
be ignored.
NOTICE
The correct dispense valve option must be
selected. Selecting an incorrect dispense valve
option will lead to erratic machine performance.