Appendix D - ADM Event and Error Codes Overview
70
313873J
Error Codes
Error
Code
Error Name
Error Description
Error
Type
Cause
Solution
0500
Invalid
Weight Cal.
Data
The three point calibration data
is invalid, system will operate
in weight mode but will attempt
to volumetrically calculate
weight. This will lead to
consistent shots which will be
offset for the desired dispense
amount.
Deviation Invalid data
Re-calibrate the machine
05A1
Invalid Auto
Cal. Data
The system will ignore the
calibration data gathered and
will use information gathered
during dispenses
Deviation Invalid data
If any messages appeared indicating why the
calibration failed attempt to fix the problem then
re-run the calibration
A4A6
Red Blanket
Overcurrent
An over current was detected
on the output
Alarm
Bad heaters
Measure resistance of heater
A4B5
Blue Blanket
Overcurrent
Alarm
A4A3
Red Inline
Overcurrent
Alarm
A4B1
Blue Inline
Overcurrent
Alarm
A4A2
Red Hose
Overcurrent
Alarm
A4B4
Blue Hose
Overcurrent
Alarm
A4A7
Red Chiller
Overcurrent
Alarm
High voltage
Measure voltage across the disconnect switch.
Voltage should measure between 190 and 264 Vac.
A4B8
Blue Chiller
Overcurrent
Alarm
Shorted Temperature
Control Module
If temperature rises for a zone that has been disabled,
replace Temperature Control Module
A4H1
Motor Over
Current
High current has been
detected on a phase and has
been shutdown to prevent
damage
Alarm
Bad internal wiring of the
motor
Replace motor
Short circuit of motor
wiring
Check wiring to the motor to ensure no bare wires are
touching and that no wires are shorted to ground
A4M1
Motor Over
Current
Too much current is being
drawn from the wall
Alarm
Low voltage from the wall
during load
Make sure the supply line is properly sized for the
load and is above the minimum voltage requirements
A4N1
Motor Over
Current
A hardware current fault has
occurred causing a system
shutdown
Alarm
Short circuit of motor
wiring
Check wiring to the motor to ensure no bare wires are
touching and that no wires are shorted to ground
Motor rotor has become
locked
Unplug the directional valve (so pressure will not
build) and try to move the motor again. If this
succeeds then the power pack may need to be
replaced. If the motor is still unable to move, the
bearings or hydraulic pump have likely failed in the
motor and will need to be replaced.
A7A6
Red Blanket
Control Fault
Unexpected current to
heater/chiller
Alarm
Shorted Temperature
Control Module
If temperature rises for a zone that has been disabled,
replace Temperature Control Module
A7B5
Blue Blanket
Control Fault
Alarm
A7A3
Red Inline
Control Fault
Alarm
A7B1
Blue Inline
Control Fault
Alarm
A7A2
Red Hose
Control Fault
Alarm
A7B4
Blue Hose
Control Fault
Alarm
A7A7
Red Chiller
Control Fault
Alarm
A7B8
Blue Chiller
Control Fault
Alarm