Figure 15 Shielded Hose 24M732
Connection at WB100 Enclosure
Figure 16 Unshielded Hose 24M733
Dimensions at WB100 Enclosure
Figure 17 Unshielded Hose 24M733
Connection at WB100 Enclosure
b.
Non-Graco Isolated Enclosure:
Connect
hose as instructed in the isolation system
manual.
For
For
For Shielded
Shielded
Shielded Hose
Hose
Hose Systems:
Systems:
Systems:
Conductive hose layer (C) must be
grounded through its connection to the
isolation system’s grounded enclosure (L)
or grounded fence. To maintain grounding
continuity, the conductive hose layer (C)
must be engaged in the ferrule when the
strain relief nut is tightened. Failure to
properly install the hose in the strain relief
could result in an electric shock.
Figure 18 Shielded Fluid Hose Connection
at Non-Graco Isolation Enclosure
c.
Connect the end of the tube (T) to the pump
fluid outlet fitting (Z).
NOTE:
NOTE:
NOTE: The Graco warranty and approvals
are void if the electrostatic spray gun is
connected to a non-Graco voltage isolation
system or if the gun is operated above 60 kV.