Agitator
Agitator
Agitator Kit
Kit
Kit Accessory
Accessory
Accessory
To add an agitator to the Graco isolation system, order
Part No. 245895. See
,
for the kit parts list.
1.
Discharge the system voltage (see
Discharge and Grounding Procedure, page 39
).
2.
Relieve the pressure (see
Pressure Relief Procedure, page 39
3.
Open the isolated enclosure door.
4.
Remove the back of the control box (258).
5.
Remove tube (A2) from elbow (282) at the air
manifold; see
Install the Y fitting (402) into the elbow. Install
tubes (A2) and (407) into the Y fitting. Route the
agitator tube (407) into the cabinet.
6.
Replace the back of the control box (258).
7.
Assemble the other parts of the kit as shown.
Secure the agitator with the setscrew (408).
8.
Return the system to service.
Figure 20 245895 Agitator Kit
24
3A2496H