Round
Round
Round Spray
Spray
Spray Gun
Gun
Gun Setup
Setup
Setup Procedure
Procedure
Procedure
To achieve a round spray pattern, do the following:
1.
Install a round spray kit. See Round Spray
Accessories in
. To
achieve a soft pattern for small parts or increased
transfer efficiency, select the medium pattern or
small pattern models.
2.
Follow steps 1–11 in the
3.
Fully open the fluid adjustment valve (H)
counterclockwise.
4.
Adjust the air in the air cap.
a.
Fully close the atomizing air restrictor valve
(G) counterclockwise. Then, open the
atomizing air restrictor valve (G) one turn.
b.
Fully close the fan air adjustment valve (F)
clockwise.
5.
Turn ON (I) the ES On-Off switch (J).
6.
Set the gun air regulator to deliver a minimum
45 psi (0.32 MPa, 3.2 bar) at the gun when
triggered, to ensure full spraying voltage.
Table
Table
Table 8
8
8 ... Pressure
Pressure
Pressure Drop
Drop
Drop
Air
Air
Air Hose
Hose
Hose
Length
Length
Length in
in
in ft
ft
ft (m)
(m)
(m)
using
using
using 5/16
5/16
5/16 inch
inch
inch (8
(8
(8
mm)
mm)
mm) diameter
diameter
diameter hose
hose
hose
Air
Air
Air Regulator
Regulator
Regulator Setting
Setting
Setting
in
in
in psi
psi
psi (MPa,
(MPa,
(MPa, bar)
bar)
bar)
with
with
with gun
gun
gun triggered
triggered
triggered
15 (4.6)
55 (0.38, 3.8)
25 (7.6)
65 (0.45, 4.5)
50 (15.3)
80 (0.56, 5.6)
7.
Verify that the ES indicator (K) [Hz indicator on
Smart guns] is lit.
Table
Table
Table 9
9
9 ... LED
LED
LED Indicator
Indicator
Indicator Colors
Colors
Colors
Indicator
Indicator
Indicator
Color
Color
Color
Description
Description
Description
Green
When spraying, the indicator
should remain green, indicating
sufficient air pressure to the
alternator turbine.
Amber
If the indicator changes to amber
after one second, the air pressure
is too low. Increase air pressure
until the indicator is green.
Red
If the indicator changes to red
after one second, the air pressure
is too high. Decrease air pressure
until the indicator is green. To
maintain a higher application air
pressure, install ES On/Off Valve
Restrictor Kit 26A160. Adjust the
pressure as needed to ensure the
indicator remains green.
3A2496H