8.
Shut off the air to the gun. Turn OFF (O) the ES
On-Off switch (J).
9.
Start the pump. Adjust the fluid regulator to
achieve the production rate that you want.
NOTE:
NOTE:
NOTE: The round spray air cap is optimized for
a production rate of 5 oz/min (150 cc/min). For
best round spray results, limit the production rate
to 10 oz/min (300 cc/min) or less.
10. Turn on the air to the gun. Turn ON (I) the ES
On-Off switch (J).
11. Spray a test pattern. Check the atomization.
NOTE:
NOTE:
NOTE: If the atomization is too fine, or if the
object being sprayed is moving too much,
adjust the atomizing air restrictor valve (G)
counterclockwise slightly to limit the air flow. To
improve atomization, adjust the atomizing air
restrictor valve (G) clockwise slightly to increase
the air flow or decrease the fluid flow.
12. Adjust the pattern size.
• For the largest spray pattern, fully close the fan
air adjustment valve (F) clockwise.
• For the smallest spray pattern, fully open the
fan air adjustment valve (F) counterclockwise.
13. Spray a test piece. Examine the edges
for coverage. If wrap is poor, see
34
3A2496H