Maintenance
26
312666W
Clean Fluid Manifold
Clean fluid manifold fluid ports with compatible
solvent and brush whenever removed from
gun. Do not damage the internal sealing
surfaces. Fill fluid ports with grease if left
exposed, to seal out moisture.
Clean or Replace Fluid Screens
1. Follow
2. Relieve pressure in hose manifold after gun
is removed.
a. Place the fluid manifold over containers,
facing away from you.
b. Ensure fluid valves are closed.
c. Very slowly open fluid manifold check
valves 2 to 2-1/2 turn. Under high
pressure, fluid will spray sideways from
the fluid ports.
3. Remove fluid screens by unthreading them
from fluid manifold.
4. Clean or replace fluid screens. See
5. Carefully inspect o-rings and fluid screen
surfaces. Replace if worn or damaged.
6. Liberally lubricate o-rings and reassemble.
Use a hex nut driver to tighten.
Adjust Fluid Valve Packings
Periodic adjustment may be necessary to stop
fluid leakage. If fluid valve is leaking, adjust the
packings:
1. Follow
2. Loosen set screw and remove valve
handle.
3. Turn valve packing nut clockwise in
1/8-turn increments until leak is corrected.
4. Re-pressurize system then check for leaks.
Repeat procedure as necessary.
F
IG
. 34:
F
IG
. 35
Fluid Ports
TI12089a
TI11337a
CAUTION
To prevent cross-contamination of the check
valves, do not interchange A component and
B component parts. The A component check
valve is marked with an A.
F
IG
. 36
1/8
TI19008a