Warnings
2
3A0142A
Warnings
Pressure Relief Procedure
1.
Close the supply pump’s bleed-type master air valve
(required for pneumatic systems) (F
IG
. 1).
2.
Trigger fluid valve into a waste container until pres-
sure is relieved (F
IG
. 2).
3.
Leave the fluid valve open until you are ready to use
the system again.
If you suspect that the dispensing valve, extension, or
grease fitting coupler is clogged, or that pressure has
not been fully relieved after you have followed the steps
above,
very slowly
loosen the coupler or hose end cou-
pling to relieve the pressure gradually, then loosen it
completely. Then clear the clog.
WARNING
SKIN INJECTION HAZARD
High-pressure fluid from dispense valve, hose leaks, or ruptured components will pierce skin. This may look like just
a cut, but it is a serious injury that can result in amputation.
Get immediate surgical treatment.
•
Do not point dispense valve at anyone or at any part of the body.
•
Do not put your hand over the end of the dispense nozzle.
•
Do not stop or deflect leaks with your hand, body, glove, or rag.
•
Follow
Pressure Relief Procedure
in this manual, when you stop spraying and before cleaning, checking, or
servicing equipment.
MOVING PARTS HAZARD
Moving parts can pinch or amputate fingers and other body parts.
•
Keep clear of moving parts.
•
Do not operate equipment with protective guards or covers removed.
•
Pressurized equipment can start without warning. Before checking, moving, or servicing equipment, follow the
Pressure Relief Procedure
in this manual. Disconnect power or air supply.
F
IG
. 1
F
IG
. 2