Appendix B - Alarms
94
3A2776K
R5BE
Dosing Sizes Are Not
Optimized.
Spray
Dosing valve is operating near high
or low timing limits.
Balance A and B fluid hoses. See
XM PFP Mix Manifold manual.
Or change ‘B’ restriction. Check
Restriction screen.
R5DX
Uncalibrated system in
Weight Mode
Spray
System was not calibrated.
Run the
and Calibration for Ratio by
Weight Mode
to calibrate system for weight
mode. Run system in volume
mode.
Run system in volume mode.
R9BE
System detected five R4BF
(Ratio High B) or five R1BF
(Ratio Low B) alarms within
five minutes. Sprayer shuts
down for five minutes for
operator to resolve problem.
Spray
See R4BE or R1BE alarm causes.
See R4BE or R1BE alarm
solutions. Flush mixed material if
necessary, and purge off-ratio
mixed material in hose.
*T2DA
*T2DB
Temperature Exceeded
Advisory Limits.
Spray
Fluid temperature exceeded high
or low limits for more than four
minutes.
Same as T5DA or T5DB.
T3CA
T3CB
A/B Material Heater
Temperature Control
Module Over Temperature
Advisory
Always
Module is bad.
Replace module.
Cool system down.
T3CH
Hose Heater Temperature
Control Module Over
Temperature Advisory
Always
Module is bad.
Replace module.
Cool system down.
T4CA
T4CB
A/B Material Heater
Temperature Control
Module Over Temperature
Alarm
Always
Module is bad.
Replace module.
Cool system down.
T4CH
Hose Heater Temperature
Control Module Over
Temperature Alarm
Always
Module is bad.
Replace module.
Cool system down.
T4CX
Temperature Over
Temperature Switch
Always
Over temperature switch jumper
unplugged.
Replace jumper.
T4DA
T4DB
A/B Material Heater High
Temperature RTD 1 Alarm
Always
Heater bad.
Repair heater.
RTD bad.
Replace RTD.
T4DE
Hose High Temperature
RTD 1 Alarm
Always
Heater bad.
Repair heater.
Splitter cable bad.
Replace splitter cable
RTD bad in hose bundle.
Replace RTD in hose bundle.
T4DH
Hose Heater High
Temperature RTD 2 Alarm
Always
Heater bad.
Repair heater.
Splitter cable bad.
Replace splitter cable
RTD bad in hose heater outlet.
Replace RTD in hose water heater
outlet.
Alarm
Code
Alarm Problem
When
Active
Cause
Solution