Approvals
12
3A4381M
#Components (Sixth Digit of Part Number)
† OEM packages require additional components to make a complete system, see page 61.
HAZ Hazardous Location - Class 1 Division 1
EX Rated for use in explosive atmospheres
ORD Not for use in explosive atmospheres or hazardous locations
Approvals
Sixth Digit
XP-hf Pump
Assembly
Cart
Hose
and XTR
Gun
7 Gallon
Hoppers
Viscon HF
Heaters
(Primary
A&B)
Solvent
Pump
Junction
Box
Water Hose
Heater with
Circulation Pump
Location
Approval
xxxxx0 (
†
)
x
(
†
)
xxxxx1
x
x
x
HAZ, EX
xxxxx2
x
x
x
x
HAZ, EX
xxxxx3
x
x
x
240 V
x
HAZ, EX
xxxxx4
x
x
x
x
240 V
x
HAZ, EX
xxxxx5
x
x
x
x
240 V
x
x
ORD
xxxxx6
x
x
x
x
240 V
x
240 V
HAZ, EX
xxxxx7
x
x
x
x
240 V
x
x
240 V
ORD
xxxxx8
x
x
x
x
480 V
x
x
ORD
xxxxx9
x
x
x
x
480 V
x
x
480 V
ORD
Pump Packages
without Pump Lowers
Includes:
Part
System Ratio
Maximum Fluid Working
Pressure psi (MPa, bar)
Cart
XTRxxx Spray Gun and 35 ft (10.7 m)
Supply hose (not attached)
572000(#)
70:1
7250 (50, 500)
X
X
573000(#)
50:1
5000 (34, 344)
X
X
# These pump packages without pump lowers are not operational and are not CE or Ex marked.
All systems CE marked except where noted.
All systems with a part number ending in 0, 1, 2, 3, 4, and 6 are
Ex rated for use in explosive atmospheres except where noted.
II 2 G
Ex h IIA T3 Gb