Flush Mixed Material
3A4381M
35
6. Open the solvent flush valve (AD)
7. Disengage the trigger lock, hold the gun against a
grounded metal pail, and trigger the gun into the
pail. Use a pail lid with a hole to dispense through.
Seal around the hole and gun with a rag to prevent
splash back. Be careful to keep fingers away from
the front of the gun. Continue flushing until clean
solvent dispenses.
8. Close the solvent pump air valve (DA).
9. Hold a metal part of the gun against a grounded
metal pail and trigger the gun to relieve pressure.
Close the solvent flush valve (AD) after relieving the
pressure.
10. Engage the trigger lock. Disassemble and clean the
spray tip with solvent by hand. Reinstall the spray
tip on the gun.
AD
DA
4)!