Maintenance
10
312145K
Maintenance
Flushing
Flush the pump and gun before fluid can dry in it. If
available, use flushing procedure provided in your pump
manual instead of this procedure.
1.
Follow the
Pressure Relief Procedure
, page 6.
Engage the trigger lock.
2.
Remove the spray tip and guard from gun. Clean
with solvent.
3.
Put the pump intake in a grounded pail of
compatible solvent.
4.
Start the pump at its lowest pressure.
5.
Disengage trigger lock, then trigger the gun into the
paint pail. When solvent appears, release trigger.
6.
Trigger the gun into solvent pail. Circulate fluid until
the system is thoroughly flushed.
7.
Follow the
Pressure Relief Procedure
, page 6.
Engage the trigger lock.
Cleaning and Replacing Filter
(Not applicable for XTR510, XTR706, and
17V677)
1.
Follow the
Pressure Relief Procedure
, page 6.
Engage the trigger lock.
2.
Disconnect the trigger guard from the gun body by
pushing up on the guard hook and pulling it out of
the notch.
3.
The trigger guard beneath the gun handle can then
be used as a wrench to loosen the nut.
4.
When the alignment notches are no longer
engaged, use your hand to twist the handle and
remove it from the gun head.
5.
Remove the filter.
6.
Clean the filter using a soft brush.
7.
Replace the filter.
8.
Apply a light coating of grease to the threads and
then attach.
9.
Use the trigger guard to tighten the nut.
10. Reattach the trigger guard to the gun.
Cleanup
Flush the gun after each work shift and store in a dry
location. Do not leave the gun or any parts in water or
cleaning solvents.
Failure to clean or replace the filter or damaged
handle bore can result in serious injury.
Before performing any maintenance on the gun, read
all warnings in this manual and relieve pressure.
ti5052a
ti5054a
Summary of Contents for XTR 5
Page 13: ...Repair 312145K 13 ...