DataTrak Operation
311164M
21
Prime/Flush
1.
See F
IG
. 5. To enter Prime/Flush mode, press any
key to wake up the display, then press
. The
Prime/Flush symbol will appear flashing in the dis-
play and the LED will flash
.
2.
While in Prime/Flush mode, runaway protection is
disabled and the batch totalizer (BT) will not count.
3.
To exit Prime/Flush mode, press any key to wake up
the display, then press
. The Prime/Flush sym-
bol will disappear from the display and the LED will
stop flashing.
Counter/Totalizer
See F
IG
. 5. The last digit of the batch totalizer (BT) rep-
resents tenths of gallons or liters. To reset the totalizer,
press any key to wake up the display, then press and
hold
for 3 seconds.
Display
See F
IG
. 5. The display (Y) will turn off after 1 minute of
inactivity in Run mode or 3 minutes in Setup mode.
Press any key to wake up the display.
Diagnostics
DataTrak can diagnose several problems with the pump.
When the monitor detects a problem, the LED (W, F
IG
.
5) will flash and a diagnostic code will appear on the dis-
play. See Table 3.
To acknowledge the diagnosis and return to the normal
operating screen, press
once to wake up the display,
and once more to clear the diagnostic code screen.
NOTE: If flow rate is set to
both totaliz-
ers will display the number of pump cycles.
/min,
NOTE: DataTrak will continue to count cycles
when display is off.