Place high pressure gauge (10,000 psi) on load sense test port. Switch crawler travel speed to high speed.
See Figure 12.
Run engine at full RPM. Depress left hand travel pedal for forward travel. Stall the track, pressure should be
4,300 - 4,500 psi. Adjust front port relief as required.
See Figure 12.
Leave high pressure gauge (10,000 psi) on load sense test port. Repeat above for reverse travel. Adjust rear port
relief as required.
See Figure 12.
Leave high pressure gauge (10,000 psi) on load test port and repeat test for right hand travel forward and
reverse.
See Figure 12.