E
X P R E S S
3 7 0
8–45
A C W i r i n g O n e - L i n e D i a g r a m
V
A
A
SHORE # 1
SHORE # 2
TRANSFER
30A
30A
70A
50A
X
X
NOTE:
WHEN OPERATING FROM A SINGLE POWER SOURCE WITH THE TRANSFER SWITCH
ENGAGED, THE AMP READINGS MUST BE ADDED FOR PROPER LOAD MANAGEMENT.
AC VOLTS
30A
MECHANICAL
INTERLOCK TO
PREVENT
SIMULTANEOUS
CLOSURE
AC AMPS
AC AMPS
BATTERY CHARGER
BOW THURSTER CHARGER
MICROWAVE
STOVE
REFRIGERATOR
GALLEY OUTLET
CABIN OUTLET
WATER HEATER
HEAD OUTLET
COCKPIT OUTLET
AIR / COOLER PUMP
15A
5A
15A
25A
15A
15A
15A
15A
15A
15A
5A
30A
15A
30A
CURRENT TRANSFORMER
CURRENT TRANSFORMER
GENERATOR
(SELF LIMITING)
LOAD GROUP 1
LOAD GROUP 2
SPDT SELECT SWITCH
30A
AIR CONDITIONER
COCKPIT COOLERS
HELM AIR COND.
MECHANICAL
INTERLOCK TO
PREVENT
SIMULTANEOUS
CLOSURE
GRILL
15A
5A
ACCESSORY