46
Work steps
Cleaning agents
Procedure
Cleaning device
Notes
1. Preparatory
measures
Close the cutting
thickness adjust-
ment.
Pull the mains plug.
2. Dismount the
removable parts
according to the
operating manual
3. Coarse cleaning
Manual
Removing the
product residues
with a
Plastic scraper
Plastic scraper, also
with removable
parts.
Immediate begin-
ning
4. Cleaning
2 % “P3 sterile“,
for example. Acting
time: approx. 15
min (also see prod-
uct data sheet)
after thorough
pre-flushing with
(max. 40°) water;
acting time approx.
20 minutes
Brush, tub,
Cleaning cloth,
Hand spraying
device
all dismounted and
stationary machine
parts
4. Disinfecting
Additional
measure
0.5 -2%
„P3-alcodes“
Acting time: see
product data sheet
manual spraying
Do not exceed the
acting time accord-
ing to the product
data sheet
One-way cleaning
cloth, hand spray-
ing device
additional protec-
tion, Spacing while
spraying approx.
30 mm
5. Rinsing
Drinking water
Temperature
max. 50 °
One-way cleaning
cloth
Remaining machine
Hand spraying
device
removed parts
Water hose
removed parts
6. Checking
visually for optical
cleanliness
7. Drying
rubbing dry
in the open air
Let dry
One-way cleaning
cloth
Machine, Put
dismounted parts
apart as possible
8. Maintaining
Oils for the food-
stuffs sector with
H1 approval
Application by
spraying or rubbing
One-way cleaning
cloth
Prior to starting
work, rinse all
parts that get into
contact with the
cutting material
9. Mounting
mounting takes
place in reverse or-
der to dismounting
(Operating manual)
Personnel must
have clean and
disinfected hands
10. Precautionary
measures
Cover the machine when cleaning the environment with a spraying device
6.3 Cleaning schedule