Press the „
OK
“ button to alter the respective switching points. The value to be altered will
begin to blink. The value may then be adjusted by using the „ “ and the „ “ buttons.
Press the “
OK
” button again when the displayed value should be accepted.
16
SWITCHING POINTS
PUMP ON
0-100% 8%
PUMP OFF
0-100% 6%
Pump OFF
(The numerical value is always
smaller than with Pump ON.)
key „OK“
Pump ON
(The numerical value is always
smaller than with Valve ON.)
VALVE ON
0-100% 10%
VALVE OFF
0-100% 12%
Supply with mains drinking water -
OFF
Supply with mains drinking water - ON
(The
numerical value is always smaller than with
Valve OFF.)
DW INTERVAL
0-14 DAYS 14
Flush the drinking water supply piping every
14
days. The value „0“ switches the flushing
off.
Flush the drinking water supply pipes for 30
seconds.
DW DURATION
0-60 SEC 30
Cleaning the rainwater filter every
14
days
The value 0 switches the cleaning process off.
CLEANER INTERVAL
0-14 DAYS 14
Cleaning the rainwater filter for
5
seconds
CLEANER DURATION
0-60 SEC 5
CLEANER RINSE AT
INCREMENT 2%
Picture 10: Sub-menu “Switching points”
Main menu level
Cleaning the rainwater filter when the fill level
has increased by 2% after rainfall. If the fill
level continues to increase, the rinsing will be
repeated every 3 hours.
The value 0 switches
the cleaning process off.
Summary of Contents for 351021
Page 27: ...Space for your notes 27 ...