7.
Error messages and fault correction
The operation of the system control is to be checked at regular intervals (at
the latest every 4 weeks).
The read out reports always represent only probabilities; e.g. no clear localization by the
device is possible for overlaying faults.
Please also take note that the system control device cannot identify any
malfunction of the house water system.
(No malfunction signal is supplied by
the house water system to the system control device).
If faults are recognized by the sensors the system control cannot continue to work
inde-
pendently.
The particular faults are shown on the plain text in the display:
18
ERROR
SENSOR
The reason for this error is that the white
sensor cable has been damaged.
ERROR
DL SHORT CIRCUIT
Error possibilities:
-The data cable of the measurement pick-up
is not connected to the data cable terminal
[14]
but has been connected to the sensor
terminal
[15/16]
- Cinch plug or the cinch connector has a short
circuit
- Wires of the data cable have been damaged
ERROR
SENSOR CONTROL
The measurement sensor delivers no
signal and must be replaced.
ERROR
SENSOR SYSTEM
For further diagnosis, remove the stainless
steel weight
[22]
out of the water. If the error
indication has now stopped, then the sensor it
self was the cause of the fault. If the error
indication should continue, this implies that the
measurement pick-up is defect.
ERROR
NO
SIGNAL
The communication between the system
control to the measurement pick-up is
interrupted.