9. Fault messages and rectification
42 / 54
9.
Fault messages and rectification
Technical system operation faults (failure of a unit) are indicated both visually and acoustically.
The control unit's acoustic fault signal can be deactivated by pressing
. The optical error
display is only acknowledged once
is pressed again.
If the power supply fails, an integrated non-mains-dependent power cut detector emits an alarm
which alternates with a visual signal. If this happens, no acknowledgement can be performed.
Voltage!
During all work on the machine cabinet extending beyond operating
the control unit, the cabinet should be disconnected from the mains
voltage.
Fault message on display
9.1
Error message as text on the liquid crystal display
Operating telltale lights up red
Display
Liquid crystal display
Possible cause
Rectification
KLbasic /
KL24base
KLplus /
KL 24plus
No display, no lamp
Power supply is inter-
rupted
Check the power supply to the system
and control unit
Check microfuse F1 on the supply cable
Check the position of the maintenance
switch (position 1)
If the buffer is flat, mains failure will not be
indicated acoustically or optically.
No display, lamp green
Switch off system and switch on again
after 10 seconds.
No / faint display
Contrast is set incorrect-
ly
Press and hold Esc key and use arrow
keys to adjust contrast.
Set clock
Set clock
Internal time/date not
set
Go to Time and date to set
Compresofail-
ure
**error**
compressor
error
Compressor not working
/ not drawing power
Check main fuse F1
Check compressor in manual mode
Valve 1
failure
valve 1 error
Valve not working
Fuse tripped
Solenoid defective
Valve blocked by dirt
Check valve in manual mode
Check microfuse of consumers F2
Check valve for traces of powder
Unscrew valve from metal strip and check
for contamination and remove any found
Valve 2
failure
valve 2 error