5
.
Installation of the setting-up kit
47
/
144
Assembly information for pipe aerators
•
Wrap Teflon tape around stainless steel
thread 10 times
•
Seal any connections not needed with caps
•
Screw on diaphragm pipes by hand
•
Unperforated areas must be aligned to the
top and bottom
•
Do not install damaged diaphragm pipes
•
Screw on diaphragm pipes at end to avoid
the risk of damage
Perforated areas
5.3
Inserting the aerators into the tank/tanks
The prefitted aerators are inserted into the SBR tank/tanks.
Positioning of the two-disc aerator
Positioning of the three-disc aerator
Positioning of the diaphragm pipe aerator
The aerators are weighted down with concrete
blocks. These are pushed through the downpipe.
The diaphragm pipes should be fitted to installations with diaphragm pipe aerators only when access is no