Reference & Installation Manual 7
5.5 Confidential Mode
S
ECTION
[002]: O
PTIONS
[4]
AND
[5]
For UL installations, Confidential Mode must be disabled
(option [4] = OFF)
If Confidential Mode is enabled and actions are not performed on the Grafica
keypad for a period of time, the LCD screen will display the time, date and all
LEDs on the keypad will turn off until either a key is pressed, or an code # is
entered. The period of time in which no action is performed is defined by the
Confidential Mode Timer (section 5.10 on page 9).
Grafica will switch from Confidential Mode to Normal Mode once a key is
pressed or a code # (PIN) is entered. In normal mode, Grafica displays the
date, time and the status of the zones for every partition assigned to the
keypad. In addition, the alarm memory, bypassed zones and troubles will
also be displayed.
S
ECTION
[002]: O
PTION
[4]
Option [4] OFF = Normal Mode (default)
Option [4] ON = Confidential Mode
S
ECTION
[002]: O
PTION
[5]
Option [5] OFF = Exit confidential mode by entering an code # (PIN)
(default)
Option [5] ON = Exit confidential mode by pressing any key
Section [002] option [5] will work only if option [4] in section [002] is
enabled.
5.6 Exit Delay Beep
S
ECTION
[002]: O
PTION
[6]
The keypad can beep once every second or play a selected tone during the
Exit Delay Timer. During the final 10 seconds only the beep tone will be
heard (at a faster interval) to provide a final warning before the area is armed.
Option [6] OFF = Exit Delay beep is disabled
Option [6] ON = Exit Delay beep is enabled (default)
5.7 Keypad Input Type
S
ECTION
[002]: O
PTION
[7]
Grafica’s keypad input (section 3.5 on page 4) can be utilized as a zone or
as an input for an optional external temperature sensor (section 2.3.2 on
page 3). If set as a temperature input, Grafica represents it as the outside
temperature on the System Status screen next to the word “OUT”.